EN
RayClouds Photoelectric Technology Co.,Ltd.
RayClouds Photoelectric Technology Co.,Ltd.
RT-200A Response Time Measurement Device

RT-200A Response Time Measurement Device

RT-200A Response Time Analyzer is an optical instrument independently developed by RayClouds. High sensitivity PMT sensor, low noise, high sensitivity board design. It is the best device for gray-scale response time and flicker measurement.

RT-200A Response Time Measurement Device Overview

Optional RT-200M Response Time ModuleOptional RT-200M Response Time Module, the function of the Response Time Module is equivalent to the instrument,
which can be combined with the system to finish response time and flicker measurement, etc.

RT-200A Response Time Measurement Device Characteristic

High Sensitivity
  • High Sensitive PMT Sensor
  • Low Noise,High Sensitive Board Design

Luminance Measurement
  • Luminance as low as 0.001cd/m2
  • Built in CMOS image sensor

High Speed • High Accuracy
  • Iterative Precision:±1%(Lv)
  • Accuracy:±3%(Lv)
  • Sampling rate up to 500Kbs

RT-200A Response Time Measurement Device Advantage

Luminance, GAMMA and flicker
  • Telephoto lens and 1ºangle  design
  • Filter near CIE Y curve
High Accuracy Response Time Measurement
  • μs Response speed, 2M data storage
  • Multiple filter design
  • Gray to Gray response time measurement
Flicker
  • Accurate Measurement with High Frequency
  • Simultaneous measurement FMA and JEITA modes
Image Control
  • Standard image signal generator and PC graphics card output

RT-200A Response Time Measurement Device Specification

Model

RT-200A

RT-200M

Receptor

PMT(CIE 1931 Y Filter)

Working Distance

400mm~∞

Viewing Angle

Image

CMOS Sensor

Sampling Rate

1K~500Kbs/S

A/D

16bit

Sampling Length

2,000,000

Trigger

Software and External

Luminance

Measurement Range

0.001 to10,000cd/m2

Accuracy*¹

±3%

Repeatability(σ)*¹

±1%

Flicker

FMA

Display range:0~100%;Accuracy:±1%

JEITA

Measurement range: 10 cd/m2

Frequency range:0~250HZ

Accuracy:±0.5db

Measurement Analysis

Data filtering

Low pass, High pass, Band pass, Band stop, Smooth

FFT

Arbitrary length Fast Fourier Transform

VESA Standard

Adaptive filtering

2D and3D Graph and data export EXCEL

Interface

USB2.0

Operating temperature

5 to50ºC

Input Voltage

AC Adapter,DC12V/2A output

*1. Measurement of luminance in the RayClouds conditions(using the 100cd/m2 standard A light source) .
*Specifications and appearance are subject to change without prior notice.